VAP-404PT

4+4 ZONES, DEVELOPED ALARM CONTROL PANELS PLASTIC BOX

VAP-404PT

Zones

Ÿ VAP-404: 4 zones on main control panel,
expandable to 8 zones with optional zone
expansion module or with hardwire zonedoubling.
Ÿ VAP-408: 8 zones on main control panel,
expandable to 12 zones with optional zone
expansion module or to 16 zones with
hardwire zone-doubling.
Ÿ VAP-416: 16 zones on main control panel,
expandable to 20 zones with optional zone
expansion module or to 32 zones with
hardwire zone-doubling.
Ÿ Using each zone with NC or NO contacts
devices with or without EOL resistors.
Ÿ Selecting each zone as 12 different type (door,
window, home, away, 24 hours, fire, tamper,
panic…etc.)
Ÿ Entry/Exit delays for each partition.
Ÿ
Ÿ Additional features of the zones (Entry/exit
zone, follower zone, last-door zone, zone with
audio / silent…etc.)
Ÿ Arming panel automatically without delay
time by determining Entry/Exit zones, when
someone exits from last-door.
Ÿ Adjusting each zone as special zone in order
to transmit alarm message to the central
station without alarm siren. (for gas detectors,
flood detectors)
Ÿ Selectable cross zone and double hit features
to avoid from false alarm.
Ÿ Walking test for each zone.
Ÿ Bypassing each zone manually or
automatically.

Other Informations

Output


Adjusting cut off time between 2 to 255
minutes.
1 siren output :
Negative or positive trigger.